1 / 3
CY-FC Series Flameproof Balance (Internal Calibration)
The Aczet CY-FC Series Flameproof Balance is an analytical balance in a flameproof enclosure for hazardous areas. The CY 224FC reads 0.1 mg up to 220 g and has motorised internal calibration. Aczet states CIMFR Dhanbad certification for Zone 1 and 2, Gas Group IIB.
Specifications across the series
These are ranges for the whole CY-FC Series Flameproof Balance (Internal Calibration) line. Each model has its own exact values: see the brochure below or ask our team and we will confirm the right model for you.
- Model
- CY 224FC
- Readability (mg)
- 0.1
- Weighing capacity (g)
- 220
- Minimum load (mg)
- 10
- Repeatability, sd (mg)
- 0.1
- Linearity (mg)
- ± 0.2
- Tare range, subtractive (g)
- -220
- USP minimum weight (mg)
- 160 (typical)
- Minimum weight, U = 1%, k = 2 (mg)
- 16 (typical)
- Pan size (mm)
- Ø 90
- Response time (sec.)
- 2 to 3
- Calibration and adjustment
- Motorised internal calibration
- Hazardous-area certification (as stated by Aczet)
- CIMFR Dhanbad, Zone 1 & 2, Gas Group IIB, IS/IEC 60079-0:2011; flameproof cum weatherproof enclosure with glass window
- Display
- Alphanumeric backlit LCD
- Units
- gm, mg, ct, GN, mo, oz, dwt, t1T, t1H, t1S, mom, Bat, MS
- Operating temperature (°C)
- 15 to 35
- Sensitivity drift (ppm/°C)
- ± 2
- Interface
- RS 232C, USB optional (Windows direct communication)
- Application modes
- PCS, % weighing, animal / dynamic weighing, check weighing, automatic density determination, formulation, automatic statistic calculator
- Power supply
- DC adapter, input 100 to 240 V / 0.8 A, output 13 V, 50 / 60 Hz (current printed as 15 A, probably 1.5 A)
- Compliance
- ISO, GLP / GMP & USP
- Balance size, W × D × H (mm)
- 517 × 302 × 130
- Weight, approx. (kg)
- 16.3
Key features of CY 224FC
0.1 mg readability to 220 g
CY 224FC reads 0.1 mg with 0.1 mg repeatability and 0.2 mg linearity.
Motorised internal calibration
Built-in weight calibration, no external test weight needed for routine adjustment.
Flameproof cum weatherproof enclosure
Cast aluminium rotary switch, water-resistant push buttons and a glass window.
Double compression glands
Aczet lists them to keep hazardous gases or powders out of the enclosure.
Backlit LCD, GLP clock
Large readable display with a built-in clock for GLP documentation.
Key advantages of CY 224FC
For hazardous industries
Designed for chemical, pharma, oil and gas, mining and defence use.
Calibrate in place
Internal weight lets users keep the balance where it is installed.
Overload awareness
Built-in capacity tracker helps protect the weighing cell.
Standard compliance claims
Aczet lists ISO, GLP / GMP and USP chapters 41 and 1251.
Custom ranges on request
Aczet states customised flameproof balances are available.
About CY 224FC
The Aczet CY-FC Series Flameproof Balance is made for laboratories and plants where flammable gases or vapours may be present, such as chemical, pharmaceutical, oil and gas, mining and defence sites. The CY 224FC is the internal-calibration model: 220 g capacity, 0.1 mg readability and 0.1 mg repeatability.
Flameproof construction
The electronics sit in a flameproof cum weatherproof enclosure with a glass window. Aczet lists a cast aluminium rotary switch, water-resistant push buttons and double compression glands that keep hazardous gases or powders out of the enclosure. A protective cover is supplied.
Certification (Aczet statement)
Aczet states that CIMFR Dhanbad certification covers use in Zone 1 and 2 for Gas Group IIB as per IS/IEC 60079-0:2011. Please ask us for the certificate for the exact model before you plan an installation.
Weighing technology
The balance uses an electromagnetic force compensation (EMFC) weigh sensor and a built-in capacity tracker that helps prevent overloading. The motorised internal weight lets you calibrate without handling an external test weight.
Everyday use
A large backlit LCD, a built-in clock for GLP documents, a round bubble level and adjustable feet make set-up simple. Built-in applications include piece counting, percentage weighing, check weighing, density determination, formulation and statistics, and there is an RS 232C interface (USB optional).
Aczet also offers customised flameproof ranges on request. Tell our team your capacity and hazardous-area class and we will confirm the right model.
Documents & research papers
Frequently asked questions: CY 224FC
Aczet lists the CY 224FC (printed CY 224F-C on the datasheet): 220 g capacity, 0.1 mg readability, with motorised internal calibration.
The CY-FC has motorised internal calibration. The CY-F models use external calibration with a test weight.
Aczet states CIMFR Dhanbad certification for use in Zone 1 and 2, Gas Group IIB, as per IS/IEC 60079-0:2011. Ask us for the certificate for the model you buy.
Repeatability is 0.1 mg and linearity is 0.2 mg.
Minimum load is 10 mg. Aczet gives a typical USP minimum weight of 160 mg and 16 mg for U = 1 percent.
It has an RS 232C interface, with USB (Windows direct communication) optional.
Aczet lists an anti-vibration pad, dot-matrix data printer, test weights, density kit, 21 CFR Part 11 PC software and a qualification document.
Enquire about CY 224FC
Share your requirement and our team will get back to you.
Similar products
Alternatives with a similar purpose and specifications, including other brands.
/